VCF Calculators
Sizing helpers for VMware Cloud Foundation 9 / vSAN 9. Estimates only โ validate final designs with the official vSAN ReadyNode Sizer.
1 ยท Cluster
2 ยท Disks per host
3 ยท Storage policy (data protection)
4 ยท Reserved capacity & overheads
5 ยท Licensing (VCF 9 subscription)
Validation & design checks
Where does the raw capacity go?
Policy comparison for this hardware
Licensing
Rules & best practices used by this calculator
Storage policies โ minimum hosts and capacity multiplier
| Policy | Layout | Multiplier | Min hosts | Recommended | Notes |
|---|---|---|---|---|---|
| RAID-1, FTT=1 | 2 replicas + witness | 2.00ร | 3 (2-node + witness) | 4 | Only option for 2-node / hybrid friendly |
| RAID-1, FTT=2 | 3 replicas | 3.00ร | 5 | 6 | |
| RAID-1, FTT=3 | 4 replicas | 4.00ร | 7 | 8 | |
| RAID-5, FTT=1 (OSA) | 3+1 | 1.33ร | 4 | 5 | All-flash only |
| RAID-5, FTT=1 (ESA) | 2+1 (3โ5 hosts) / 4+1 (6+ hosts) | 1.50ร / 1.25ร | 3 / 6 | 4 / 7 | Adaptive RAID-5, layout changes with host count |
| RAID-6, FTT=2 | 4+2 | 1.50ร | 6 | 7 | OSA: all-flash only |
OSA vs ESA โ what is configurable
| Item | OSA | ESA |
|---|---|---|
| Device layout | Disk groups: 1โ5 per host, each 1 cache + 1โ7 capacity devices | Single storage pool, all devices = capacity (NVMe TLC only). Up to 24 devices/host |
| Cache tier | Required. All-flash: 100% write buffer (max 1.6 TB used per DG in vSAN 8+). Hybrid: 70% read / 30% write; cache โฅ 10% of consumed capacity | None |
| Media | All-flash (SAS/SATA/NVMe) or Hybrid (SSD + HDD) | NVMe only, ESA-certified ReadyNodes |
| RAID-5/6 | All-flash only, RAID-5 = 3+1 | Always available; adaptive RAID-5 (2+1 / 4+1); RAID-5/6 with RAID-1 performance |
| Data reduction | Cluster-wide: Compression-only or Dedup & Compression (all-flash only). D&C: a capacity-disk failure takes the whole DG offline | Compression on by default (per-policy, at ingest). VCF 9: global deduplication |
| Failure domain | Cache device failure = whole disk group fails | Single device failure only affects that device |
| Operations reserve | Typically ~10โ17% of capacity (lower with larger / more devices) | Much lower โ estimate โ hosts ร 765 GB + per device min(5%,100 GB) + min(0.25%,100 GB) |
Reserved capacity (slack space)
Operations reserve โ space for internal operations (resync, rebalancing, policy changes, object re-layout). Enabling it prevents VMs from consuming it.
Host rebuild reserve โ capacity of one host (โ 1/N of the cluster), so all data can be rebuilt after a host failure. Requires โฅ 4 hosts; not available for 2-node or stretched clusters, and requires the operations reserve to be enabled.
Legacy guidance โ before vSAN 7 U1, keep 25โ30% slack space free (keep consumption < 70%).
Units โ drives are sold in decimal TB (10ยนยฒ); vCenter and vSAN licensing use binary TiB (2โดโฐ). 1 TB = 0.909 TiB.
1 ยท VCF version & deployment model
2 ยท Management components
3 ยท Add-ons
4 ยท Workload domains
5 ยท Management cluster fit check
Validation & design checks
Where do the resources go?
Bill of materials: management domain appliances
Management cluster fit check
Sources, assumptions & rules
Deployment model defaults (VCF Installer)
Appliance size reference
Rules & notes
VCF 9.1 reconciles with the official totals. With the default profiles, the tool's vCPU, RAM and disk totals match Broadcom's VCF Fleet Sizing Models exactly. First instance: Simple 76/251/7448, HA Small 106/335/8422, HA Medium 184/656/11445, HA Large 298/949/15357 (vCPU / GB RAM / GB disk). The disk of the VCF Management Services nodes is derived from those totals.
VCF Management Services (9.1) is a Kubernetes-based runtime: control-plane nodes plus worker nodes. Fleet lifecycle, SDDC lifecycle, Identity Broker, Software Depot, telemetry, Log Management and Real-time Metrics run there. Log Management upscales every worker (Small log size โ Large workers 16/32, Medium or Large โ X-Large workers 24/48). Log Management and Real-time Metrics also add workers as demand grows. The worker count is estimated as demand ร headroom (1.09 CPU, 1.2 RAM) รท worker size, + 1.
VCF 9.0 has no Management Services. It uses separate appliances: a VCF Operations fleet management appliance and VCF Operations for Logs (a cluster needs at least 3 nodes). The 9.0 profiles are based on published appliance sizes. They are not official totals.
NSX sharing. VI workload domains can share one NSX Manager instance (up to 14 domains, single overlay transport zone, same BOM and upgrade schedule). The management domain's NSX can never be shared with a VI workload domain.
Not included: workload-domain NSX Edges and Avi Service Engines (they run in the workload domain), Supervisor control-plane VMs, vDefend SSP, HCX, backup and other third-party VMs. The VCF Installer appliance is converted into SDDC Manager, so it isn't counted separately.
Disk figures for the cloud proxy, Log Management storage, Real-time Metrics and VCF Operations for Networks are estimates. Validate final designs with the official VCF Planning & Preparation Workbook.