vSphere Calculators

VCF Calculators

Sizing helpers for VMware Cloud Foundation 9 / vSAN 9. Estimates only โ€“ validate final designs with the official vSAN ReadyNode Sizer.

1 ยท Cluster

2 ยท Disks per host

ESA uses a single-tier storage pool: no cache tier, no disk groups. All devices contribute capacity. Compression is on by default; VCF 9 adds global deduplication.

3 ยท Storage policy (data protection)

Nested fault domains (vSAN 7 U3+): survive a host failure and a disk / DG failure on the surviving host.

4 ยท Reserved capacity & overheads

5 ยท Licensing (VCF 9 subscription)

Minimum 16 cores licensed per CPU.
RAW licensable capacity
โ€“
vSAN datastore (after metadata)
โ€“
Net usable (protected)
โ€“
Effective (with data reduction)
โ€“

Validation & design checks

    Where does the raw capacity go?

    Policy comparison for this hardware

    Same hardware, reserves and overheads โ€“ only the storage policy changes. Highlighted row = selected policy.

    Licensing

    vSAN is licensed per TiB of raw claimed capacity (OSA: capacity tier only, cache tier is not counted). VCF/VVF entitlement is pooled across the entitlement, so a shortfall here may be covered elsewhere โ€“ otherwise a vSAN capacity add-on is needed.

    Rules & best practices used by this calculator

    Storage policies โ€“ minimum hosts and capacity multiplier
    PolicyLayoutMultiplierMin hostsRecommendedNotes
    RAID-1, FTT=12 replicas + witness2.00ร—3 (2-node + witness)4Only option for 2-node / hybrid friendly
    RAID-1, FTT=23 replicas3.00ร—56
    RAID-1, FTT=34 replicas4.00ร—78
    RAID-5, FTT=1 (OSA)3+11.33ร—45All-flash only
    RAID-5, FTT=1 (ESA)2+1 (3โ€“5 hosts) / 4+1 (6+ hosts)1.50ร— / 1.25ร—3 / 64 / 7Adaptive RAID-5, layout changes with host count
    RAID-6, FTT=24+21.50ร—67OSA: all-flash only
    OSA vs ESA โ€“ what is configurable
    ItemOSAESA
    Device layoutDisk groups: 1โ€“5 per host, each 1 cache + 1โ€“7 capacity devicesSingle storage pool, all devices = capacity (NVMe TLC only). Up to 24 devices/host
    Cache tierRequired. All-flash: 100% write buffer (max 1.6 TB used per DG in vSAN 8+). Hybrid: 70% read / 30% write; cache โ‰ฅ 10% of consumed capacityNone
    MediaAll-flash (SAS/SATA/NVMe) or Hybrid (SSD + HDD)NVMe only, ESA-certified ReadyNodes
    RAID-5/6All-flash only, RAID-5 = 3+1Always available; adaptive RAID-5 (2+1 / 4+1); RAID-5/6 with RAID-1 performance
    Data reductionCluster-wide: Compression-only or Dedup & Compression (all-flash only). D&C: a capacity-disk failure takes the whole DG offlineCompression on by default (per-policy, at ingest). VCF 9: global deduplication
    Failure domainCache device failure = whole disk group failsSingle device failure only affects that device
    Operations reserveTypically ~10โ€“17% of capacity (lower with larger / more devices)Much lower โ€“ estimate โ‰ˆ hosts ร— 765 GB + per device min(5%,100 GB) + min(0.25%,100 GB)
    Reserved capacity (slack space)

    Operations reserve โ€“ space for internal operations (resync, rebalancing, policy changes, object re-layout). Enabling it prevents VMs from consuming it.

    Host rebuild reserve โ€“ capacity of one host (โ‰ˆ 1/N of the cluster), so all data can be rebuilt after a host failure. Requires โ‰ฅ 4 hosts; not available for 2-node or stretched clusters, and requires the operations reserve to be enabled.

    Legacy guidance โ€“ before vSAN 7 U1, keep 25โ€“30% slack space free (keep consumption < 70%).

    Units โ€“ drives are sold in decimal TB (10ยนยฒ); vCenter and vSAN licensing use binary TiB (2โดโฐ). 1 TB = 0.909 TiB.